There are multiple possibilities for why TigerTouch may not find your TigerStop®. We’ll cover most of the causes and how to troubleshoot them
Enable Code:
- If you have never connected the two, is your machine properly enabled for TigerTouch?
- See the following page on finding your current enable code, and send it over to TigerStop® Technical support at service@tigerstop.com to verify that it is properly enabled. Please see our page on how to find your existing enable code.
Tigerlink 6 Stealing Communication Port:
- This is by far the most common cause of TigerTouch not finding your TigerStop®. Start by bringing up the Tigerlink 6 UI screen via double clicking the Tigerlink icon in your system tray

- Once the UI is up in front of you, we’re checking for two things:
- First is if you see a serial number under the Devices drop down menu
- Second is if auto-connect is checked.
- We do not want either of these things! TigerLink can connect directly to a Tigerstop®, but since you’re using TigerTouch, we do not want Tigerlink 6 to connect as the machine has only one communication port

- If you see a serial number in devices or auto-connect is checked, uncheck auto-connect and restart Tigerlink 6.
- Now Tigerlink 6 should no longer be stealing our port, try to launch TigerTouch
Trying to launch TigerTouch while the TigerStop® is moving:
- If you try to launch TigerTouch while the machine is moving, it will fail to detect a machine.
- The reasoning for this is the Tigerstop® is sending information as it moves, and if it’s currently sending information out, it can’t establish the proper connection with TigerTouch.
- Wait until the TigerStop® is no longer moving and is fully at rest and try to re-launch TigerTouch
Physical connection not being seen:
- To confirm this, we’ll want to launch Device Manager
- In the windows search bar, type in Device Manager and hit enter
- Once device manager is open, look for something that says Ports (COM & LPT) and expand it

- Once expanded, you’re looking for your usb-to-serial adapter to appear here. The default we include with a tablet package is the SeaLink RS232
- If you do not see Ports (COM & LPT) at all, or you don’t see your usb-to-serial adapter:
- If this was previously working, try moving the adapter to a different USB port on the USB hub or connecting it directly to the tablet, by-passing the USB Hub entirely.
- If this is a replacement tablet going onto an existing machine, you most likely need to download the proper drivers for your usb-to-serial adapter
- Here is a link to the drivers for the SeaLink RS232 adapter that TigerStop® uses
If you’ve tried all of the above and still cannot connect, please reach out to Tigerstop® technical support