How do I set up my ESC with DeviceInstaller? - TigerStop

Call Us

TigerStop Customer Service

Phone: +1 (360) 448 6102

TigerStop Sales

Phone: +1 (360) 254 0661 ext 2

TigerStop Headquarters

Phone: +1 (360) 254-0661

 

 

Select Your Location

Setting up an ESC with DeviceInstaller Quick-start Guide

The Lantronix DeviceInstaller software can be downloaded HERE:

https://www.lantronix.com/products/deviceinstaller/

Preparation:

1. Ensure ESC is plugged into ethernet cable and serial cable to TigerStop®
2. Ensure ESC and TigerStop® are plugged in and powered on
3. Note which serial port on ESC the serial cable is plugged in to (1 or 2)
4. Note Baud Rate of TigerStop® (In ‘System Info” Menu – 9600 works best)

Step One:

1. Download and install the Lantronix DeviceInstaller software
2. Run DeviceInstaller
3. In the LH column the lantronix device will show up
4. Expand menu (“+” boxes) until it displays the IP address (figure 1) – write down the IP address for later
5. Click on IP address to highlight it – the RH column will change
6. Click on the Web Configuration tab above the RH column
7. Click on the Green Arrow to the right of the address bar (figure 2)
8. Click “OK” on the Windows security box that pops up

Lantronix Figure 1.1
Lantronix Figure 1.1
Lantronix Figure 2.1
Lantronix Figure 2.1

Step Two:

1. Click on “Network” at top of Purple box
2 Click the “Use the following IP configuration” radio button 3. Enter the following settings:

  • IP Address: The IP address from Part One, step 4
  • Subnet Mask: 255.255.255.0
  • Default Gateway: Fist 6 numbers of IP address and 0.0 (example: 192.168.0.0) DNS Server: Leave blank

4. Click OK button on bottom of screen (important)

Step Three:

1. Click on “Serial Settings” (in purple box) for whichever channel TigerStop® is plugged into on ESC (1 or 2)
2. Select baud rate that TigerStop® is set to (drop down box)
3. Click OK button on bottom of screen (important)
4. Click on “Connection” (in purple box) for whichever channel TigerStop® is plugged into on ESC (1 or 2)
5. Note Local Port setting – it will be 10001/10002 or 14001/14002
6. Click OK button on bottom of screen (important)

Step Four:

1. Click “Apply Settings” – Device Installer will reboot ESC and progress bar will show when complete
2. Exit out of Device installer
3. Re-open DeviceInstaller and confirm that settings by following steps one through three & just looking at the settings this time
4. Close DeviceInstaller

Step Five:

1. Navigate to TigerLink Appdata folder:

  • Click Winows icon lower LH side of screen and type: %appdata%
  • Open Appdata folder and scroll down to TigerLink folder and open

2. Open TigerStopDevices.xml file with notepad
3. Make the following changes:

  • <baudrate> set to TigerStop® & ESC baudrate
  • <serialNumberName> should match the TigerStop® serial number <displayName> should match the TigerStop® serial number
  • <ipAddressString> is the IP address from step one
  • <ipPort> is the local port noted in step three

4. Save

Step Six:

1. Open TigerLink
2. Ensure the “Auto Connect” checkbox is checked. If not, check it, then close/re-open the program.
3. TigerStop® serial number should be displayed in the “Devices” box
4. If so, ESC is configured correctly and TigerStop® is connected

VERY IMPORTANT:
Never click “Find All” again. That resets all the settings on the ESC, and then this process would need to be repeated
It’s a good idea to remove the “Find All” button from the TigerLink 6 interface entirely
This can be accomplished by editing the disableFindAll.txt file to say TRUE instead of FALSE
That file can be found in the same location referenced in step five

If TigerLink 6 ever fails to connect in the future, then:

1. Make sure the TigerStop® is on
2. Check all the physical connections
3. Make sure the “Auto Connect” checkbox is checked in the TigerLink 6 interface
4. Close and reopen TigerLink 6