arrow-L-teal.jpg Part List Menu

Configure Pre-Sets flag-cdn-qc-35.jpg flag-mx-35.jpg

plist-pset-types-300-E.JPG

Configure Pre-Sets lets the user choose to run pre-sets in set point, pusher or increment mode. Configure pre-sets is a list parameter.

Default for this parameter is Set Point.

  1. Press [B] or [C] to scroll through the options.

  2. Press [D] to save selection and exit to the Ready Screen.

arrow-R-teal.jpg Pre-Set Edit

arrow-R-teal.jpg How do pre-sets work in set point mode?

Pre-sets configured as set point will move the stop to the position indicated by the absolute value of the pre-set.

  • Example: A pre-set value of 15" will move the stop to 15", regardless of the current position of the stop.

arrow-R-teal.jpg How do pre-sets work in pusher mode?

Pre-sets configured as pusher will move the stop TOWARD the tool by the value of the pre-set PLUS the kerf value.

  • Example: From a starting position of 60", a pre-set value of 5" will move the stop to 54.875" (when the kerf value = .125").

arrow-R-teal.jpg How do pre-sets work in increment mode?

Pre-sets configured as increment will move the stop TOWARD the tool by the absolute value of the pre-set (kerf is NOT applied).

  • Example: From a starting position of 60", a pre-set value of 5" will move the stop to 55".