Running Min-Max

The Min-Max routine defines TigerStop's operating range length of travel by detecting the position of the end sensors at both extremities of the aluminum fence extrusion.

Min-Max is an auto-setup mode a routine which TigerStop automatically executes in order to establish parameter values and should be run ONLY after the stop has run through the home routine a set of automatic actions that verify TigerStop's parameters at every power on. Min-Max should be the ONLY method used to change minimum or maximum parameters. See also, When to Run Min-Max.

  1. At the Ready screen press and HOLD and at the same time, then quickly release.

  2. The screen displays .

Make sure NOTHING is in the path of the stop!

  1. Press again.

The stop will move to both ends of the fence extrusion, first to the far end the end of the fence beam farthest from the motor, then to the motor end the end of the fence beam closest to the motor.

The minimum and maximum parameter values are now changed and saved.