TigerStop Manual
Running auto-test requires that you choose
two positions, one near the motor and the other near the far end, and
program these two positions alternately into the first 10 hot
keys another name for the GoSet function, which stores programmable lengths
behind key combinations 1 to 99.
When auto-test is run, the stop will travel between these two positions
until you press the STOP button.
How to set up Auto-Test
At the Ready screen press
to start entering the “hot
keys.” For
a complete run down on how to program and use "hot keys", see
Making
Hot Keys
.
Use 8" and 50" as the near
and far positions.
To run auto-test for your machine, choose as the far position a length at the far end of your TigerFence instead of 50" as in this example.
To run auto-test on a metric TigerFence, you can use 200mm and 1270mm, approximate metric equivalents of the positions used in this example.
Press
to enter the first (near) length
and then
to view it

.
Press to advance to the next hot key.
Press
to enter the next
(far) length and then
to view it

.
You can automatically advance to the next hot key by
pressing after each entry.
Now, program hot keys 3 to 10 alternately with
8" and 50" as above,
and then press
to save them and exit the "hot keys"
program.
Auto-test will NOT run correctly unless ALL 10 hot keys are programmed!
Press
to
access the Calib* Motion menu
, and then enter your
and press
.
Press
repeatedly until you see
, enter your
again, and then
.
Make sure NOTHING is in the path of the fence!
Press
to change the parameter
value from 0 (inactive) to 1 (active).
TigerFence immediately starts running the auto-test, coursing back and forth between the close and far positions you programmed in hot keys 1 to 10.
Press
to stop running auto-test.